1028R-WC1R




Integrated Board
Super X10DRW-i

Key Features
1. Dual socket R3 (LGA 2011) supports
    Intel® Xeon® processor E5-2600 v3
    family; QPI up to 9.6GT/s
2. Up to 1TB ECC DDR4 2133MHz;
    16x DIMM sockets
3. 2x PCI-E 3.0 x16 (FHHL) slots 4. 10x Hot-swap 2.5" SAS/SATA HDD
    bays
5. SAS3 (12Gbps) via LSI 3108 6. Intel® i350 Dual port GbE LAN 7. I/O ports: 2x SuperDOM, 1x VGA,
    1x COM, 6x USB 3.0 (4 rear, 2 front)
8. Optional 2x 2.5" NVMe drives support 9. 700W Redundant Power Supplies
    Platinum Level High-efficiency
Available Colors: Black    

 

Product SKUs
SYS-1028R-WC1R
  • SuperServer 1028R-WC1R (Black)
 
Motherboard

Super X10DRW-i
 
Processor/Cache
CPU
  • Intel® Xeon® processor E5-2600 v3 family (up to 145W TDP **)
  • Dual Socket R3 (LGA 2011)
Cores / Cache
  • Up to 18 Cores / Up to 45MB Cache
System Bus
  • QPI up to 9.6 GT/s
Note ** Please contact your Supermicro sales representative for additional details.
 
System Memory
Memory Capacity
  • 16x 288-pin DDR4 DIMM sockets
  • Up to 1TB ECC LRDIMM, 512GB ECC RDIMM
Memory Type
  • 2133/1866/1600MHz ECC DDR4 SDRAM 72-bit
DIMM Sizes
  • RDIMM: 32GB, 16GB, 8GB, 4GB
  • LRDIMM: 64GB, 32GB
Memory Voltage
  • 1.2 V
Error Detection
  • Corrects single-bit errors
  • Detects double-bit errors (using ECC memory)
 
On-Board Devices
Chipset
  • Intel® C610 Chipset
SATA
  • SATA3 via Intel® C610; RAID 0, 1
SAS
  • SAS3 (12Gbps) via LSI 3108
  • RAID 0, 1, 5, 6, 10, 50, 60 support
  • 2GB DDR3 Cache
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
  • ASPEED AST2400 BMC
Network Controllers
  • Intel® i350 Dual Port Gigabit Ethernet Controller
  • Virtual Machine Device Queues reduce I/O overhead
  • Supports 10BASE-T, 100BASE-TX, and 1000BASE-T, RJ45 output
  • 1x Realtek RTL8211E PHY (dedicated IPMI)
Graphics
  • ASPEED AST2400 BMC
 
Input / Output
Serial ATA
  • 2x SATA3 (6Gbps) ports
SAS
  • 8x SAS3 (12Gbps) ports
LAN
  • 2x RJ45 Gigabit Ethernet LAN ports
  • 1x RJ45 Dedicated IPMI LAN port
USB
  • 6x USB 3.0 ports (4 rear + 2 via header)
VGA
  • 1x VGA port
Serial Port / Header
  • 1x Fast UART 16550 header
DOM
  • 2x SuperDOM (Disk on Module) ports
 
PC Health Monitoring
Voltage
  • Monitors for CPU Cores, +1.8V, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory Voltages.
  • 5+1 Phase-switching voltage regulator
FAN
  • 6x 4-pin fan headers (up to 6 fans)
  • 6x fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • CPU thermal trip support
  • Thermal Control for 8x Fan Connectors
  • Thermal Monitor 2 (TM2) support
  • PECI
LED
  • CPU / System Overheat LED
  • Suspend static indicator LED
  • UID/Remote UID
Other Features
  • Chassis intrusion detection
  • Chassis intrusion header
  • SDDC Support
  • RoHS
Chassis
Form Factor
  • 1U Rackmount
Model
  • CSE-116AC2-R706WB
 
Dimensions and Weight
Width
  • 17.2" (437mm)
Height
  • 1.7" (43mm)
Depth
  • 23.5" (597mm)
Gross Weight
  • 46 lbs (20.9kg)
Available Colors
  • Black
 
Front Panel
Buttons
  • Power On/Off button
  • UID button
LEDs
  • Power status LED
  • HDD activity LED
  • 2x Network activity LEDs
  • Universal Information (UID) LED
 
Expansion Slots
PCI-Express
  • 2 PCI-E 3.0 x16 full-height, Half-length slots
 
Drive Bays
Hot-swap
  • 10 Hot-swap 2.5" SAS / SATA HDD trays (connected to onboard storage controller)
 
Backplane
SAS/SATA HDD Backplane
Optional 2x 2.5" NVMe drives
 
System Cooling
Fans
  • 5x 4cm heavy-duty counter-rotating fans w/ air shroud and optimal fan speed control
 
Power Supply
700W/750W Redundant AC-DC high-efficiency power supply with PMBus and I2C
AC Voltage
  • 700W: 100 - 140 V, 50-60 Hz
  • 750W: 200 - 240V, 50-60 Hz
DC Output +5V standby
  • 3 Amp
DC Output +12V
  • 700W: 58 Amp @ 100-140V
  • 750W: 62 Amp @ 200-240V
Certification Platinum Level Certified   Platinum Certified
  (Cert. in progress)
 
System BIOS
BIOS Type
  • 128Mb SPI Flash EEPROM with AMI BIOS
BIOS Features
  • Plug and Play (PnP)
  • APM 1.2
  • PCI 2.3
  • ACPI 1.0 / 2.0 / 3.0 / 4.0
  • BIOS resuce hot keys
  • USB Keyboard support
  • SMBIOS 2.7.1
  • UEFI 2.3.1
 
Management
Software
Power Configurations
  • ACPI / APM Power Management
  • Power-on mode for AC power recovery
 
Operating Environment / Compliance
RoHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature:
       10°C to 35°C (50°F to 95°F)
  • Non-operating Temperature:
       -40°C to 70°C (-40°F to 158°F)
  • Operating Relative Humidity:
       8% to 90% (non-condensing)
  • Non-operating Relative Humidity:
       5% to 95% (non-condensing)
Parts List - (Items Included)
  Part Number Qty Description
Motherboard / Chassis MBD-X10DRW-i
CSE-116AC2-R706WB
1
1
Super X10DRW-i Motherboard
1U Chassis
Backplane BPN-SAS3-116A-N2 1 Backplane support 8x 2.5" SAS2/SAS3/SATA3 HDD/SSD on device ID[1-8], with SGPIO. Support 2x 2.5" PCIe NVMe SSD on device ID[9-10] - with PCIe x1,x2,x4 support, max 25W/slot.,RoHS/REACH,PBF
Cable 1 CBL-SAST-0568 1 Internal Mini-SAS HD to Mini-SAS HD 35cm,30AWG,12Gb/s,HF,RoHS/REACH,PBF
Cable 2 CBL-CDAT-0662 1 8 pin to 8 pin round SGPIO cable, 61.5cm, 28AWG, pinout 1-1,RoHS/REACH
Cable 3 CBL-0484L 2 55cm 30AWG SATA S-S cable
Cable 4 CBL-SAST-0550 1 Internal Mini-SAS HD to Mini-SAS HD 25cm,30AWG,HF,RoHS/REACH,PBF
Riser Card RSC-R1UW-2E16-O-P 1 RSC-R1UW-2E16-O-P
Heatsink / Retention SNK-P0047PSC 1 1U Passive Front CPU Heat Sink w/ a Side Air Channel for X9, X10 Systems Equipped with a Narrow ILM MB
Heatsink / Retention SNK-P0057PS 1 1U High Performance Passive CPU Heat Sink for X9, X10 Systems Equipped w/ a Narrow ILM MB
Power Supply PWS-706P-1R 2 1U 750W redundant power width 54.5mm(Platinum),HF,RoHS/REACH,PBF
Add-on Module AOM-S3108M-H8-O-P 1 SAS3 (12Gbps) via LSI 3108 RAID controller
Optional Parts List
  Part Number Qty Description
Cable for Storage Controller Card Connection CBL-0343L-01 1 IPASS to 4 SATA Cable, 30AWG 76/66/54/45CM, W/ 66CM
Network Card(s) AOC-SGP-i2
AOC-SGP-i4
AOC-SG-i2
AOC-SG-i4
AOC-STG-b4S
AOC-STGN-i2S
AOC-STG-i2T
AOC-STG-i2
-
-
-
-
-
-
-
-
Standard LP, 2x GbE RJ45, PCI-E x4, Intel®i350AM2
Standard LP, 4x GbE RJ45, PCI-E x4, Intel®i350
Standard LP, 2x GbE RJ45, PCI-E x4, Intel®82575EB
Standard LP, 4x GbE RJ45, PCI-E x4, Intel®82576EB
Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom®BCM57840S
Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel®82599ES
Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel®X540
Standard LP, 2x 10GbE CX4, PCI-E x8, Intel®82598EB
Storage Controller Card(s) AOC-S3008L-L8e
AOC-S3008L-L8i
AOC-S3108L-H8iR
 
AOC-S2308L-L8e
AOC-S2308L-L8i
AOC-S2208L-H8iR
 
AOC-SAS2LP-MV8
AOC-SAS2LP-H4iR
 
AOC-SAS2LP-H8iR
 
-
-
-
 
-
-
-
 
-
-
 
-
 
Standard LP, 8 internal ports (12Gb/s) Gen-3, 122HDD, HBA
Standard LP, 8 internal ports (12Gb/s) Gen-3, 63HDD, RAID 0,1,1E
Standard LP, 8 internal ports (12Gb/s) Gen-3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
Standard LP, 8 internal ports (6Gb/s) Gen-3, 122HDD, HBA
Standard LP, 8 internal ports (6Gb/s) Gen-3, 63HDD, RAID 0,1,1E
Standard LP, 8 internal ports (6Gb/s) Gen-3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
Standard LP, 8 internal ports (6Gb/s) Gen-2, HBA
Standard LP, 4 internal & 4 external ports (6Gb/s) Gen-2, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
Standard LP, 8 internal ports (6Gb/s) Gen-2, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60
Cable CBLSAST-0590 - Internal Mini-SAS HD cablefor PCIe SSD NVMe, 70cm,30AWG
NVMe AOC card AOC-SLG3-2E4R - Standard LP, 2 internal NVMe ports, x4 per port, Gen-3
SuperCap BTR-TFM8G-LSICVM02 - SuperCap package
CachVault(s) BTR-TFM8G-LSICVM02 - CacheVault for AOM LSI 3108 (LSICVM02)
CacheVault Installation Kits MCP-240-00127-0N
BKT-BBU-BRACKET-05
-
-
SuperCap installation kit for thick 2.5" HDD location
SuperCap installation kit for PCI-E location
Onsite Service Program OS4HR3/2/1 - 3/2/1-year onsite 24x7x4 service
Onsite Service Program OSNBD3/2/1 - 3/2/1-year onsite NBD service